Overview:

 

This is a power supply that converts standard AC power into the desiredvoltage and frequency using a power conversion circuit. lts main features include providingclean and reliable sinusoidal power output, low harmonic distortion, high frequency andvoltage stability, and the ability to simulate different voltage and frequency characteristicsfound in various parts of the world. lt is suitable for applications such as factory productionlines, quality testing, and research and development.

 

 

Features:

Frequency Conversion Power Supply

Strong overload capaaity: The power unit is modular and can withstand twice the ratedcurrent without causing a voltage drop.

Fast dynamic response: Transient voltage change under sudden load increase is less than1%, and the recovery time is less than 20ms.

Excellent human-machine interaction: It uses a 7-inch touchscreen display with a resolutionof 800*480.

Strong anti-interference capability: Utilizing fiber optic drive control, it possesses extremelystrong resistance to electromagnetic interference and high reliability.

High protection level: The equipment cabinet surface is treated with electrostatic powdercoating, and the PCBs are treated with conformal coating and potting compound.

 

 

 

Circuit Block Diagram

 

Frequency Conversion Power Supply

 

Application Industries 

 

 

This automated system is used in various applications for testing AC power source effects, inlaboratories and metrology facilities for various precision tests, and can also serve as acentralized power supply for factories and laboratories.

 

Product Applications

Frequency Conversion Power Supply

 

External Dimensions

 

 

Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
AC60-11005440 460 133 
AC60-11010440 460 133 
AC60-11030440 460 242 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
AC60-11050350 560 670 
AC60-11100400 650 800 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
AC60-11200500 820 1100 
AC60-11300520 1160 1360 

 

 

Technical Parameters

 

 

Unit TypeAC60AC60AC60AC60AC60AC60AC60AC60
-11005 -11010 -11030 -11050 -11100 -11150 -11200 -11300 
Rated Power0.5kVA1kVA3kVA5kVA10kVA15kVA20kVA30kVA
Input Communication Indicators      
Power Supply System                                                                                            Single-phase two-wire + PE
Voltage Range220V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                                                             Single-phase two-wire + PE
Voltage RangeLow-end:0~150VL-N , high-end:0~300VL-N
Current range (low setting)    4A9A27A45A90A136A181A272A
Current range (highsetting)  2A4A13A22A45A68A90A136A
Frequency RangeFixed frequency:50/60Hz frequency modulation45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency                                                                                                                      ≥ 90%
Overload Capacity120%~150% , 1min; 150%~200% 2s;≥ 200% immediate output shutdown.
System Functions
Memory FunctionIt can remember the last output mode and parameters after power failure and recovery.
Protect FunctionOutput overvoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and Communication
Local OperationDigital LEDDisplay screen
Display Aesolution     Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display AccuracyVoltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote communication              No communicationRS 485/LAN
Communication Protocol     No communication protocolStandard Modbus RTU/Modbus TCPIP
Safety performance 
Compressive Strength 2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working Environment       It can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling methodForced air cooling
Protection levelIP 20
Altitude5000m@2000m Reduced usage
SizeW*D*Hmm440*460*133
(with base)
440*460*133
(with base)
440*460*242
(with base)
350*560*670
     (with wheels)
400*650*800
(with wheels)
400*650*800
(with wheels)
500*820*1100
(with wheels)
520*1160*1360
(with wheels)

 

Unit TypeAC60AC60AC60AC60AC60AC60AC60
-31100 -31150 -31200 -31300 -31450 -31600 -311000 
Rated Power10kVA15kVA20kVA30kVA45kVA60kVA100kVA
Input Communication Indicators      
Power Supply System                                                                                                    Three-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                                                                  Single-phase two-wire + PE
Voltage RangeLow setting:0~150VL-N High setting:0~300VL-N
Current range (low setting)    90A136A181A272A409A545A909A
Current range (high setting)   45A68A90A136A204A272A454A
Frequency RangeFixed frequency:50/60Hzfrequency modulation45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency≥ 90%
Overload Capacity120%~150% , 1min; 150%~200% 2s ;≥ 200% , Immediately shut off the output
System Functions
Quick settings function Multiple output voltages and frequencies can be customized.
Memory Function It can remember the last output mode and parameters after power failure and recovery.
Protect FunctionOutputovervoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and Communication 
Local OperationDigital LEDLCD Display
Display AesolutionVoltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display AccuracyVoltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote communication                                                                                                           RS 485/LAN
Communication Protocol                                                                                    Standard Modbus RTU/Modbus TCPIP
Safety performance
Compressive Strength   2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Work environmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling methodForced air cooling
Protection levelIP 20
Altitude≤ 5000m@>  2000mReduced usage
SizeW*D*H) mm400*650*800
(With Wheels)
400*650*800
(With Wheels)
500*820*1100
     (With Wheels)
500*820*1100
     (With Wheels)
520*1160*1360
(With Wheels)
520*1160*1360
(With Wheels)

650*1420*1470
(With Wheels)

     

Unit TypeAC60AC60AC60AC60AC60AC60AC60AC60AC60
-33100 -33200 -33300 -33450 -33600 -33900 -331000 -331200 -331500 
Rated Power10kVA20kVA30kVA45kVA60kVA90kVA100kVA120kVA150kVA
Input Communication Indicators        
Power Supply System                                                                                                       Three-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                                                                           Three-phase four-wire + PE
Voltage RangeLow-end:0~150VL-N high-end:0~300VL-N
Current range (low setting)  30A60A   90A136A181A272A303A363A454A
Current range (high setting)  15A30A   45A68A90A136A151A181A227A
Frequency RangeFixed frequency: 50/60Hz, Frequency modulation: 45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency≥ 90%
Overload Capacity120%~150%, 1 min; 150%~200%, 2 s; 200%, immediately shut off output.
System Functions
Quick settings function Multiple output voltages and frequencies can be customized.
Memory Function It can remember the last output mode and parameters after power failure and recovery.
Protect Function Output overvoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and communication
Local Operation LCD Display
Display Aesolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote communication RS 485/LAN
Communication Protocol Standard Modbus RTU/Modbus TCPIP
Safety performance 
Compressive Strength 2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Working EnvironmentForced air cooling
Protection levelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Size(W*D*H)mm500*820*1100
(with wheels)
500*820*1100
(with wheels)
520*1160*1360
(with wheels)
520*1160*1360
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)

 

Unit TypeAC60AC60AC60AC60AC60AC60AC60AC60AC60
-332000 -333000 -334000 -336000 -338000 -3310000 -3312000 -3316000 -3320000 
Rated Power200kVA300kVA400kVA600kVA800kVA1000kVA1200kVA1600kVA2000kVA
Input Communication Indicators        
Power Supply System                                                                                                               Three-phase four-wire+PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                         Three-phase four-wire+PEThree-phase three-wire+PE
Voltage Range0~300VL-N0~265VL-N
Current range303A454A606A911A1215A1519A1823A2431A3038A
Frequency RangeFixed frequency: 50/60Hz, Frequency modulation: 45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency≥ 90%
Overload Capacity     120%~150%,1min;150%~200%,2s;≥ 200%, Immediately cut off the output
System Functions
Quick settings function       Multiple output voltages and frequencies can be customized.
Memory function  It can remember the last output mode and parameters after power failure and recovery.
Protection function Outputovervoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and Communication 
Local Operation LCD display
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication RS 485/LAN
Communication protocol Standard Modbus RTU/Modbus TCPIP
Safety Performance 
Compressive Strength 2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodForced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Size  (W*D*H)mm1550*850*1985
(with wheels )
1550*850*1985
(with wheels )
1900*1100*19701900*1100*21001900*1100*21003100*900*21805400*1200*20805400*1200*20807000*1400*2080

 

 

 

 

 

No comment

Product Detail

Overview:

 

This is a power supply that converts standard AC power into the desiredvoltage and frequency using a power conversion circuit. lts main features include providingclean and reliable sinusoidal power output, low harmonic distortion, high frequency andvoltage stability, and the ability to simulate different voltage and frequency characteristicsfound in various parts of the world. lt is suitable for applications such as factory productionlines, quality testing, and research and development.

 

 

Features:

Frequency Conversion Power Supply

Strong overload capaaity: The power unit is modular and can withstand twice the ratedcurrent without causing a voltage drop.

Fast dynamic response: Transient voltage change under sudden load increase is less than1%, and the recovery time is less than 20ms.

Excellent human-machine interaction: It uses a 7-inch touchscreen display with a resolutionof 800*480.

Strong anti-interference capability: Utilizing fiber optic drive control, it possesses extremelystrong resistance to electromagnetic interference and high reliability.

High protection level: The equipment cabinet surface is treated with electrostatic powdercoating, and the PCBs are treated with conformal coating and potting compound.

 

 

 

Circuit Block Diagram

 

Frequency Conversion Power Supply

 

Application Industries 

 

 

This automated system is used in various applications for testing AC power source effects, inlaboratories and metrology facilities for various precision tests, and can also serve as acentralized power supply for factories and laboratories.

 

Product Applications

Frequency Conversion Power Supply

 

External Dimensions

 

 

Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
AC60-11005440 460 133 
AC60-11010440 460 133 
AC60-11030440 460 242 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
AC60-11050350 560 670 
AC60-11100400 650 800 
     
Product
Model
External Dimensions( mm)Schematic diagram of the external appearance
WDH
AC60-11200500 820 1100 
AC60-11300520 1160 1360 

 

 

Technical Parameters

 

 

Unit TypeAC60AC60AC60AC60AC60AC60AC60AC60
-11005 -11010 -11030 -11050 -11100 -11150 -11200 -11300 
Rated Power0.5kVA1kVA3kVA5kVA10kVA15kVA20kVA30kVA
Input Communication Indicators      
Power Supply System                                                                                            Single-phase two-wire + PE
Voltage Range220V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                                                             Single-phase two-wire + PE
Voltage RangeLow-end:0~150VL-N , high-end:0~300VL-N
Current range (low setting)    4A9A27A45A90A136A181A272A
Current range (highsetting)  2A4A13A22A45A68A90A136A
Frequency RangeFixed frequency:50/60Hz frequency modulation45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency                                                                                                                      ≥ 90%
Overload Capacity120%~150% , 1min; 150%~200% 2s;≥ 200% immediate output shutdown.
System Functions
Memory FunctionIt can remember the last output mode and parameters after power failure and recovery.
Protect FunctionOutput overvoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and Communication
Local OperationDigital LEDDisplay screen
Display Aesolution     Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display AccuracyVoltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote communication              No communicationRS 485/LAN
Communication Protocol     No communication protocolStandard Modbus RTU/Modbus TCPIP
Safety performance 
Compressive Strength 2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working Environment       It can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling methodForced air cooling
Protection levelIP 20
Altitude5000m@2000m Reduced usage
SizeW*D*Hmm440*460*133
(with base)
440*460*133
(with base)
440*460*242
(with base)
350*560*670
     (with wheels)
400*650*800
(with wheels)
400*650*800
(with wheels)
500*820*1100
(with wheels)
520*1160*1360
(with wheels)

 

Unit TypeAC60AC60AC60AC60AC60AC60AC60
-31100 -31150 -31200 -31300 -31450 -31600 -311000 
Rated Power10kVA15kVA20kVA30kVA45kVA60kVA100kVA
Input Communication Indicators      
Power Supply System                                                                                                    Three-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                                                                  Single-phase two-wire + PE
Voltage RangeLow setting:0~150VL-N High setting:0~300VL-N
Current range (low setting)    90A136A181A272A409A545A909A
Current range (high setting)   45A68A90A136A204A272A454A
Frequency RangeFixed frequency:50/60Hzfrequency modulation45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency≥ 90%
Overload Capacity120%~150% , 1min; 150%~200% 2s ;≥ 200% , Immediately shut off the output
System Functions
Quick settings function Multiple output voltages and frequencies can be customized.
Memory Function It can remember the last output mode and parameters after power failure and recovery.
Protect FunctionOutputovervoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and Communication 
Local OperationDigital LEDLCD Display
Display AesolutionVoltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display AccuracyVoltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote communication                                                                                                           RS 485/LAN
Communication Protocol                                                                                    Standard Modbus RTU/Modbus TCPIP
Safety performance
Compressive Strength   2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Work environmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling methodForced air cooling
Protection levelIP 20
Altitude≤ 5000m@>  2000mReduced usage
SizeW*D*H) mm400*650*800
(With Wheels)
400*650*800
(With Wheels)
500*820*1100
     (With Wheels)
500*820*1100
     (With Wheels)
520*1160*1360
(With Wheels)
520*1160*1360
(With Wheels)

650*1420*1470
(With Wheels)

     

Unit TypeAC60AC60AC60AC60AC60AC60AC60AC60AC60
-33100 -33200 -33300 -33450 -33600 -33900 -331000 -331200 -331500 
Rated Power10kVA20kVA30kVA45kVA60kVA90kVA100kVA120kVA150kVA
Input Communication Indicators        
Power Supply System                                                                                                       Three-phase four-wire + PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                                                                           Three-phase four-wire + PE
Voltage RangeLow-end:0~150VL-N high-end:0~300VL-N
Current range (low setting)  30A60A   90A136A181A272A303A363A454A
Current range (high setting)  15A30A   45A68A90A136A151A181A227A
Frequency RangeFixed frequency: 50/60Hz, Frequency modulation: 45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency≥ 90%
Overload Capacity120%~150%, 1 min; 150%~200%, 2 s; 200%, immediately shut off output.
System Functions
Quick settings function Multiple output voltages and frequencies can be customized.
Memory Function It can remember the last output mode and parameters after power failure and recovery.
Protect Function Output overvoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and communication
Local Operation LCD Display
Display Aesolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote communication RS 485/LAN
Communication Protocol Standard Modbus RTU/Modbus TCPIP
Safety performance 
Compressive Strength 2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Working EnvironmentForced air cooling
Protection levelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Size(W*D*H)mm500*820*1100
(with wheels)
500*820*1100
(with wheels)
520*1160*1360
(with wheels)
520*1160*1360
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)
650*1420*1470
(with wheels)

 

Unit TypeAC60AC60AC60AC60AC60AC60AC60AC60AC60
-332000 -333000 -334000 -336000 -338000 -3310000 -3312000 -3316000 -3320000 
Rated Power200kVA300kVA400kVA600kVA800kVA1000kVA1200kVA1600kVA2000kVA
Input Communication Indicators        
Power Supply System                                                                                                               Three-phase four-wire+PE
Voltage Range380V(±15%)
Frequency Range50/60Hz(±10%)
Output AC Characteristics
Power Supply System                                                         Three-phase four-wire+PEThree-phase three-wire+PE
Voltage Range0~300VL-N0~265VL-N
Current range303A454A606A911A1215A1519A1823A2431A3038A
Frequency RangeFixed frequency: 50/60Hz, Frequency modulation: 45~65Hz
Source Effect≤ 0.1%F.S
Load Effect≤ 0.1%F.S
Voltage Accuracy≤ 0.1%F.S
Frequency Accuracy≤ 0.01%F.S
Voltage Harmonics≤ 2%
Response Time≤ 5ms
Equipment Efficiency≥ 90%
Overload Capacity     120%~150%,1min;150%~200%,2s;≥ 200%, Immediately cut off the output
System Functions
Quick settings function       Multiple output voltages and frequencies can be customized.
Memory function  It can remember the last output mode and parameters after power failure and recovery.
Protection function Outputovervoltage, overcurrent, overload, and short circuit protection, internal overheat protection, etc.
Display and Communication 
Local Operation LCD display
Display Resolution Voltage: 0.1V, Current: 0.1A, Frequency: 0.1Hz, Power: 0.1kW
Display Accuracy Voltage: 0.1% F.S, Current: 0.2% F.S, Frequency: 0.01%, Power: 0.3% F.S
Remote Communication RS 485/LAN
Communication protocol Standard Modbus RTU/Modbus TCPIP
Safety Performance 
Compressive Strength 2000Vdc/60s/No breakdown
Insulation Resistance ≥ 20MΩ@500Vdc
Grounding Resistance ≤ 100mΩ
Noise ≤ 65dB(A)
Usage Environment 
Working EnvironmentIt can operate continuously for 24 hours under ambient temperatures ranging from -20℃ to 45℃ and relative humidity from 0% to 95%.
Cooling MethodForced air cooling
Protection LevelIP 20
Altitude≤ 5000m@>  2000mReduced usage
Size  (W*D*H)mm1550*850*1985
(with wheels )
1550*850*1985
(with wheels )
1900*1100*19701900*1100*21001900*1100*21003100*900*21805400*1200*20805400*1200*20807000*1400*2080

 

 

 

 

 

Frequency Converter Power Supply
Excellent Human-Machine Interaction: 7-inch 800*480 touchscreen.

Strong Overload Capacity: Modular power units withstand 3x rated current without voltage drop.

Fast Dynamic Response: <1% transient voltage change, <20ms recovery time.

Strong Anti-Interference: Fiber optic drive control for high reliability.

High Protection Level: Electrostatic powder coating + conformal coating and potting.
Long press to look detail
Long by picture save/share
Add Successfully

Frequency Converter Power Supply

enquiry
Add Successfully

Contact Us

Send your message to this supplier

  • First Name

  • Last Name

  • Email

Subscribe

Security Code
Refresh the code
Cancel
Confirm

MAIN MENU

About   |   Products   |   News     Cases

Contact

Copyright © Hebei Power Link Electric Equipment Technology Co., LTD All Rights Reserved

Service Center

Please choose online customer service to communicate

Contacts
E-mail
info@powerlinkelectric.com
Mobile/WhatsApp/Wechat
+8615531143445
Scan a QR Code
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.